NETZSCH Control Systems

for Agitator Bead Mills

Whether the basic version, integration into higher-level process control systems or data acquisition hardware and software: a wide range of control options are available for the NETZSCH agitator bead mills – talk with our experts. It should be noted that the execution of the operator terminal depends on the protection class of the machine.

 

 

NETZSCH control systems for agitator bead millsNETZSCH control systems for agitator bead mills
Su dispositivo es demasiado pequeño para mostrarse en esta tabla.
FunctionNETZSCH BASE (TetraNex® / Zeta® / Alpha®)
Display of operation, input and calculation parameters on digital displays
  • Pump speed
  • Mill speed
  • Gross mill output
  • Energy input
kWh meter
  • Is included and reset button for kWh meter to reset to zero
Shut-off functions can be selected and combined
  • Energy input
Operation and malfunction lights
  • As a set to indicate values outside the boundary limits
Emergency stop
  • Is included
Product temperature and product pressure are measured by
  • Contact thermometer 0-100°C with MAX switching-off contact
  • Contact manometer 0-6 bar with MIN/MAX I/MAX II switching-off contact
Automatic screen cleaning sequence
  • If a limit value for the product pressure is exceeded, the feed pump stops briefly and thereby effects a relief of the separator
Speed adjustment of the agitator mill and the product pump
  • Is by means of frequency inverter
Control system NETZSCH BASEControl system NETZSCH BASE
Su dispositivo es demasiado pequeño para mostrarse en esta tabla.
FunctionNETZSCH TEXT(TetraNex® / Zeta®)
Display of operation, input and calculation parameters on TEXT display
  • Pump speed
  • Mill speed
  • Peripheral speed
  • Product pressure
  • Product temperature
  • Gross mill output
  • Net mill output
  • Energy input
Input of nominal and threshold values
  • MAX product pressure
  • MAX product temperature
  • Pump speed
  • Agitator speed
Automatic operation
  • With default values
  • Machine is run up to the default values
Display of operational and error messages
  • "Refill" sealing liquid
  • MIN sealing liquid level
  • MIN sealing liquid pressure
  • MAX grinding chamber pressure
  • MAX product temperature
  • Displayed as text message
Shut-off functions can be selected and combined
  • Timer
  • Energy input
  • For passage mode, shut-down is pressure-dependent
Emergency stop
  • Is included
Product temperature and product pressure are measured by
  • Pt100 0 - 120°C
  • Pressure sensor 0 - 10 bar
  • Local contact pressure gauge with MAX switching-off contact
Automatic screen cleaning sequence
  • If a limit value for the product pressure is exceeded, the feed pump stops briefly and thereby effects a relief of the separator
Speed adjustment of the agitator mill and the product pump
  • Is by means of frequency inverter
NETZSCH Remote

Facilitates the integration of the machine control into a superordinate process control system via

  • Ethernet or
  • Profibus DP
Data aquisition system
  • MessDat
  • NETZSCH-Connect
Control system NETZSCH TEXTControl system NETZSCH TEXT

 

• With acquisition of the process parameters from the data bank • Machine is run up to the default values

Su dispositivo es demasiado pequeño para mostrarse en esta tabla.
FunctionNETZSCH GRAPH 1 (TetraNex® / Zeta®)
Display of operation, input and calculation parameters on graphic display
  •  Pump speed
  • Mill speed
  • Peripheral speed
  • Product pressure
  • Product temperature
  • Gross mill output
  • Net mill output
  • Energy input
  • Product througput (flow meter required)
  • Process status
Display of trend graph
  •  Is included
Process data bank with formulation management for a maximum of 98 product data sets
  •  Is included
Input of nominal and threshold values
  • From the data bank
Automatic operation
  •  With acquisition of the process parameters from the data bank
  • Machine is run up to the default values 
 
Definable operational mode
  • Is included
Applicable control strategiesControl of
  • Power
  • Temperature
  • Throughput (flow meter required)
Display of operational and error messages
  •  "Refill" sealing liquid
  • MIN sealing liquid level
  • MIN sealing liquid pressure
  • MAX grinding chamber pressure
  • MAX product temperature
  • Displayed as pop-up message
Shut-off functions can be selected and combined
  • Timer
  • Energy input and/or number of cycles
  • For passage mode, shut-down is pressure-dependent
Operation and malfunction lights
  • Are available as well as operator panel with LOCAL/REMOTE selector switch (functionality as an option)
Emergency stop
  • Is included
Product temperature and product pressure are measured by
  • Pt100 0 - 120°C
  • Pressure sensor 0 - 10 bar
  • Local contact pressure gauge with MAX switching-off contact
Automatic screen cleaning sequence
  • If a limit value for the product pressure is exceeded, the feed pump stops briefly and thereby effects a relief of the separator
Speed adjustment of the agitator mill and the product pump
  • Is by means of frequency inverter
NETZSCH Remote

Facilitates the integration of the machine control into a superordinate process control system via

  • Ethernet or
  • Profibus DP
Data aquisition system
  • MessDat
  • NETZSCH-Connect
Control system NETZSCH GRAPHControl system NETZSCH GRAPH
Su dispositivo es demasiado pequeño para mostrarse en esta tabla.
FunctionNETZSCH GRAPH 2 (Alpha®)
Display of operation, input and calculation parameters on graphic display
  • Pump speed
  • Mill speed
  • Peripheral speed
  • Product pressure
  • Product temperature
  • Gross mill output
  • Net mill output
  • Energy input
  • Product througput (flow meter required)
  • Process status
Input of nominal and threshold values
  • MAX product pressure
  • MAX product temperature
  • Pump speed
  • Agitator speed
Automatic operation
  • With default values
  • Machine is run up to the default values
Applicable control strategiesControl of
  • Power
  • Temperature
  • Throughput (flow meter required)
Display of operational and error messages
  • "Refill" sealing liquid
  • MIN sealing liquid level
  • MIN sealing liquid pressure
  • MAX grinding chamber pressure
  • MAX product temperature
  • Displayed as text message
Shut-off functions can be selected and combined
  • Timer
  • Energy input
  • For passage mode, shut-down is pressure-dependent
Emergency stop
  • Is included
Product temperature and product pressure are measured by
  • Pt100 0 - 120°C
  • Pressure sensor 0 - 10 bar
  • Local contact pressure gauge with MAX switching-off contact
Automatic screen cleaning sequence
  • If a limit value for the product pressure is exceeded, the feed pump stops briefly and thereby effects a relief of the separator
Speed adjustment of the agitator mill and the product pump
  • Is by means of frequency inverter
NETZSCH Remote

Facilitates the integration of the machine control into a superordinate process control system via

  • Ethernet or
  • Profibus DP
Data aquisition system
  • MessDat
  • NETZSCH-Connect
Su dispositivo es demasiado pequeño para mostrarse en esta tabla.
FunctionNETZSCH GRAPH PLUS (Alpha®)
Display of operation, input and calculation parameters on graphic display
  • Pump speed
  • Mill speed
  • Peripheral speed
  • Product pressure
  • Product temperature
  • Gross mill output
  • Net mill output
  • Energy input
  • Product througput (flow meter required)
  • Process status
Display of trend graph
  • Is included
Process data bank with formulation management for a maximum of 98 product data sets
  • Is included
Input of nominal and threshold values
  • From the data bank
Automatic operation
  • With acquisition of the process parameters from the data bank
  • Machine is run up to the default values
Definable operational mode
  • Is included
Applicable control strategiesControl of
  • Power
  • Temperature
  • Throughput (flow meter required)
Monitoring of temperature and flow rate of the cooling circuit (flow, return flow, thermosiphon vessel)
  • Is included
Automatic cooling water main valve
  • Is included
Monitoring of the bearing temperature (fixed bearing, loose bearing)
  • Is included
Display of operational and error messages
  • "Refill" sealing liquid
  • MIN sealing liquid level
  • MIN sealing liquid pressure
  • MAX grinding chamber pressure
  • MAX product temperature
  • Displayed as pop-up message
Shut-off functions can be selected and combined
  • Timer
  • Energy input and/or number of cycles
  • For passage mode, shut-down is pressure-dependent
Emergency stop
  • Is included
Product temperature and product pressure are measured by
  • Pt100 0 - 120°C
  • Pressure sensor 0 - 10 bar
  • Local contact pressure gauge with MAX switching-off contact
Automatic screen cleaning sequence
  • If a limit value for the product pressure is exceeded, the feed pump stops briefly and thereby effects a relief of the separator
Speed adjustment of the agitator mill and the product pump
  • Is by means of frequency inverter
NETZSCH Remote

Facilitates the integration of the machine control into a superordinate process control system via

  • Ethernet or
  • Profibus DP
Data aquisition system
  • MessDat
  • NETZSCH-Connect